| Protection | |
| Battery-protected and surge-only outlets | Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment |
| Boost and Trim Automatic Voltage Regulation (AVR) | Gives higher application availability by correcting low and high voltage conditions without using the battery. |
| Data line surge protection | Provides protection of connected equipment from power surges on the data lines. |
| Safety-agency approved | Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment. UL, FCC, CE, C-Tick approvals. |
| Power conditioning | Protects connected loads from surges, spikes, lightning, and other power disturbances. |
|
Convenience | |
| Audible alarms | Provides notification of changing utility power and UPS conditions. |
| Automatic restart of loads after UPS shutdown | Automatically starts up the connected equipment upon the return of utility power. |
| Automatic self-test | Periodic battery self-test ensures early detection of a battery that needs to be replaced. |
| Battery replacement without tools | Allows quick, easy battery replacement. |
| LED status indicators | Quickly understand unit and power status with visual indicators. |
| Cold-start capable | Provides temporary battery power when the utility power is out. |
| Hot-swappable batteries | Ensures clean, uninterrupted power to protected equipment while batteries are being replaced |
| Resettable circuit breakers | Enables a quick recovery from overload events. |
| Transformer-block spaced outlets | Protect equipment with input transformer blocks without blocking access to other receptacles. |
| User-replaceable batteries | Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR) |
|
Manageability | |
| Adjustable voltage sensitivity | Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications. |
| Adjustable voltage-transfer points | Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation. |
| Serial Connectivity | Provides management of the UPS via a serial port. |
| USB connectivity | Provides management of the UPS via a USB port (not available on all models). |
| Multiple mounting methods | Allows for standardization on one product for use in different environments. |
| Intelligent battery management | Micro-processor controlled battery charging and diagnostic testing ensures maximum battery life. |
| Output | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Output Power Capacity | 540 Watts/ 800 VA | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Max Configurable Power | 540 Watts/ 800 VA | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Nominal Output Voltage | 120V | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Output Connections |
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Input Nominal Input Voltage | 120V
|
Input Frequency |
47 - 63 Hz
|
Input Connections |
|
Cord Length | 6 feet (1.83 meters)
|
Input voltage range for main operations | 88 - 139V
|
Input voltage adjustable range for mains operation | 78 - 152V
| Batteries & Runtime Battery Type |
Maintenance-free sealed Lead-Acid battery with suspended electrolyte : leakproof
|
Included Battery Modules |
1
|
Typical recharge time |
8 hour(s)
|
Replacement Battery |
RBC32
|
RBC? Quantity |
1
|
Typical Backup Time | at Half Load
17.3 minutes (270 Watts)
|
Typical Backup Time | at Full Load
5.1 minutes (540 Watts)
|
Runtime Chart |
Back-UPS RS
| Energy Use/Efficiency ![]() Curve fit to measured efficiency data. All measurements taken in normal operating mode, at typical environmental conditions, with nominal electrical input and resistive load output. | Communications & Management Control panel |
LED status display with On Line : On Battery : Replace Battery and Overload indicators
| Audible Alarm |
Alarm when on battery : distinctive low battery alarm : configurable delays
| Surge Protection and Filtering Surge energy rating | 320 Joules
|
Filtering |
Full time multi-pole noise filtering : 5% IEEE surge let-through : zero clamping response time : meets UL 1449
|
Data Line Protection |
RJ-11 Modem/Fax/DSL protection (two wire single line),RJ45 10/100 Base-T Ethernet protection
| Physical Maximum Height |
9.00 inches (229 mm)
|
Maximum Width |
4.00 inches (102 mm)
| Maximum Depth |
12.76 inches (324 mm)
|
Net Weight |
20.50 lbs. (9.32 kg)
|
Shipping Weight |
22.50 lbs. (10.24 kg)
|
Shipping Height |
12.00 inches (305 mm)
|
Shipping Width |
9.00 inches (229 mm)
|
Shipping Depth |
17.00 inches (432 mm)
|
Master Carton Units |
1.00
|
Color |
Black
|
Units per Pallet |
40.00
| Environmental Operating Environment | 32 - 104 °F (0 - 40 °C)
|
Operating Relative Humidity |
0%
|
Operating Elevation | 0-10000 feet (0-3000 meters)
|
Storage Temperature | 23 - 113 °F (-5 - 45 °C)
|
Storage Relative Humidity |
0%
|
Storage Elevation | 0-50000 feet (0-15000 meters)
|
Audible noise at 1 meter from surface of unit |
45.00 dBA
|
Online Thermal Dissipation |
170.00 BTU/hr
| Conformance Regulatory Approvals |
CSA,FCC Part 15 Class B,FCC Part 68,UL 1449,UL 1778,UL Listed
|
Standard Warranty | 3 years repair or replace
|
Equipment protection policy |
Lifetime : $150000